A while back I was developing a workflow scheduler. However the run duration kept coming back negative. The runs kept finishing like 15 seconds before they started. Eventually I figured out why; the company had configured a policy to use their custom NTP server, but it was 16.7 seconds off. So my Windows laptop’s time was in the future, but the WSL VM (which ran the program) used another NTP server and was correct. In the end I just added a bodge that made the program request the time from an external server on startup to calculate an offset.


Two variables named somethingl and somethingI that had three grown developers scratching their head why the wrong variable was getting updated. This was back in the day when intellisense and colouring was way less advanced.
An actual compiler bug that wrote into the wrong register, went all the way down to assembler to realise the issue. This was on the early Xbox 360 (PowerPC) compiler.