People who joke about legos haven’t stepped on this bad boy

  • Sausager@lemmy.world
    link
    fedilink
    English
    arrow-up
    5
    ·
    4 hours ago

    Is it normal for there to be no cord attached to these? That would stop them from facing this way on the floor

    • towerful@programming.dev
      link
      fedilink
      English
      arrow-up
      9
      ·
      edit-2
      3 hours ago

      No, the cable comes out perpendicular to the pins (ie parallel to the wall).
      Which pretty much guarantees foot-pain orientation

      • cynar@lemmy.world
        link
        fedilink
        English
        arrow-up
        1
        ·
        56 minutes ago

        The type G was designed when things were designed to do their jobs. Any pain inflicted by user error was considered a learning opportunity.

        The cord coming out the bottom means the plug can’t pull out. Combined with the big, chunky plug and pins, means the cable will likely fail first if pulled. It will also fail at the live core first, leaving a safe plug in the wall.

        But yes, the foot pain is… impressive. It’s just blunt enough to not generally penetrate the skin, but it can happen.

        • NigelFrobisher@aussie.zone
          link
          fedilink
          English
          arrow-up
          6
          ·
          edit-2
          2 hours ago

          It’s so the live wire disconnects first if you pull the cable out - it’s the shortest, then neutral, then ground. Whoever designed this really thought of everything.

          • bryndos@fedia.io
            link
            fedilink
            arrow-up
            1
            ·
            6 minutes ago

            I thought that’s achieved by the different wiring lengths inside and the blue wire having to loop up and round to go into the top of the neutral leg.

          • Aggravationstation@feddit.uk
            link
            fedilink
            English
            arrow-up
            1
            ·
            53 minutes ago

            Few things make me proud to be British, but the ingenious design of our plug sockets is one of them. TBF though we do need those safety features. Mains power here is 240v as opposed to 120v like a lot of countries. One mistake with a live wire would be the last one you’d ever make.

        • towerful@programming.dev
          link
          fedilink
          English
          arrow-up
          2
          ·
          2 hours ago

          I doubt it.
          Tripping over a cable is as likely to damage the socket as it is to rip the cable out of the plug.
          Any appliance that increases risk by being unplugged should probably not be using a consumer connection…

          I think the 3 pin layout caused a lot of headaches, and the integrated fuse required a user-servicable plug.
          So it would have to be a split-shell design of some type, where the appliance cable would have to be cable-gripped to the same part as the plug/socket pins.
          Thus, a bottom-entry (heh) cable grip and a removable back plate that can only be unscrewed when it’s unplugged.
          This was all in a time of bakelite. Plastic wasn’t flexible.

          But no, I think tripping over an early bakelite g-type (I think it’s officially a g-type) plug cable would likely shatter the plug and pull the pins out of the socket… If it didn’t also damage the socket.

    • Mark with a Z@suppo.fiOP
      link
      fedilink
      English
      arrow-up
      6
      ·
      edit-2
      3 hours ago

      That’s from a power brick that came with attachments for different regions.

      I’ve handled normal plugs as well and they tend to orient themselves prongs up too.